Liner / Tank Membrane

The Liners are made by PVC, reinforced with compressed multilayer nylon mesh with options like Butyl Rubber or EPDM. Liners are pre-fabricated as one piece ‘bag’ to fit inside the water tank. These are non-sticky and chemically stabilized. With water inflow, it takes the shape of the tank. These liners are made of food grade, anti-algae material and are UV stabilized. These are also made according to anti cracking technology and tested up to 600,000 folds before any cracking.

Technical details of the Liner:

• Hardness (Test Method BS903A26): 65 + 5 IRH.
• Modulus at 300% Elongation (Test Method BS903A2): Min. 5.0 Mpa.
• Tensile Strength (Test Method BS903A2): Min. 9.0 Mpa.
• Elongation at Break: Min. 400%.
• Tear Strength (Test Method BS903A3C): Min. 30 kn/m.
• Adhesion (Test Method DIN-53337): 12da/N.
• Finishing: Glossy Lacquered (both face).

fabrionicsteel

Rain Water Storage Tanks

fabrionicsteel

Equalization Water Storage Tanks

fabrionicsteel

Agricultural Water Storage Tanks

  • ADVANTAGES

    ❖ MAGNELIS / ZAM / Zinc Alume or 600gm/ sq.meter Galvanized Steel as options for ultimate corrosion protection even at costal area or at any harsh and aggressive environment.
    ❖ Ultra-High Tensile Strength Low Alloy Steel with exceptionally high yield strength and outstanding mechanical properties like good formability, weldability, exceptional / wear & tear resistance for heavy duty industrial applications.
    ❖ Water Tanks can be designed for 250 Km/Hr wind speed and highest seismic zone consideration.
    ❖ JS 1000 Coated or 300 Series Stainless Steel Fasteners and Nozzles for highest corrosion resistance, high lubricity and less stress, Non-Toxic and FDA approval for use around food products.
    ❖ Chemically Compatible, food grade, UV Stabilized liner made of PVC compressed with multi-layer nylon mesh and liner-anti-crack technology, tested for crack prevention up to 600,000 folds.
    ❖ Extremely heavy duty and complete hot dipped galvanized roof structure with ‘I’ or ‘Z’ beam roof rafters, multiple compression beams, curved spreaders and tensioned rings. Roof peak load can be achieved up to 22,000 kg.
    ❖ Ultra-High Tensile steel makes the tanks extremely light weight which transfer low load to the platform and make it suitable for overhead installations with minimum foundation requirement and fast installation tank.
    ❖ Extremely high base steel Hardness.
    ❖ Extremely low solar heat absorption.